What’s The 1/150 Attic Ventilation Requirement?

Determining the roof ventilation requirements for residential buildings, we must go with the International Residential Code (IRC). The 2018 International Residential Code (IRC) includes section R806, which explains when roof ventilation is necessary and how to calculate it. So, What's the 1/150 attic ventilation requirement?

I will discuss more in this article. Keep reading!

A gable ventilation on a house, What's the 1/150 attic ventilation requirement?

Why Is Roof Ventilation Necessary?

Activities like cooking, bathing, and washing can all produce a lot of moisture. The building envelope and the floor might allow water vapor to pass through the ceiling.

Water vapors can reach a dew point in the attic due to the temperature difference between the attic and the conditioned space, resulting in condensation on the wood members in the attic. This may cause roof components to decay over time.

A continuous water supply to the roof creates a moisture problem in your house. When it builds upon the ceiling and walls, water might cause mold growth. The attic space must be vented to avoid any water accumulation on building components to prevent this mold growth. Large ventilation holes in the roof of your house allow air to flow through the attic, removing any moisture and lowering the potential for condensation development.

When is Roof Ventilation Needed?

Static vent installed on a shingle roof for passive attic ventilation

The International Residential Code, Section R806.1, specifies that:

Cross ventilation is required for each enclosed area of an attic and every separate space within an enclosed rafter space, as well as any roof-ventilated panels or skylights, by ventilating openings that are protected against the entry of rain or snow.

There are two situations in which attic ventilation will be required based on this code section: enclosed attics and enclosed rafter spaces.

Both options will need cross ventilation to be provided. If the attic is sectioned into separate rooms, each of them must be ventilated in the same manner as each enclosed rafter space.

Attic rooms originate when ceiling joists are added, and the rafter spaces are enclosed. Both enclosed conditioned spaces will require ventilation when a vaulted ceiling is installed.

While keeping the ventilation holes open, you must also defend them from rain, snow, birds, and other pests while allowing enough entrance.

Before we talk about how to calculate roof ventilation, let us briefly go over the 1/150 attic ventilation requirement?

Read more: How many roof vents do I need for plumbing?

What's the 1/150 attic ventilation requirement?

New construction of a home with peak on roof

The International Residential Building Code (IRC) updates on a three-year cycle. This is the first year of a four-year cycle. The following are some of the critical points and modifications in this area:

  • The legal minimum amount of attic ventilation is 1/150 (For every 150 square feet of attic floor space, you'll have 1 square foot of Net Free Area.). The length x width FLOOR OF THE ATTIC is the definition of the attic floor.
  • The number of holes can be reduced to 1/300 (i.e., 50% less), but two requirements must be met beginning 1.1.18. Previously, only one condition had to be satisfied. The IRC lobbied for this change, which is known as the ARMA Ventilation Task Force's work.
  • The requirement that "vents must be installed according to the vent manufacturer" has been reinstated for 2018. This includes: Don't mix exhaust, provide adequate intake to the exhaust vent, and so on.

For example, a 1,500-square-foot attic requires 10 square feet of ventilation. If you wish to compute the area in square inches, multiply 144 by 10. The necessary amount is 1,440 square inches (10 X 144 divided by 10).

Let's assume that the ventilation area of one aperture you have is 300 square inches. Divide 1,440 square inches by 300 square inches to get 4.8. As a result, take your opening and divide it by the amount of ventilation provided (in this case, 4.8).

The required number of ventilation ports to be provided shall be 5. You can also calculate it here.

Exceptions to the Roof Ventilation Calculation

Ribbed metal roof under blue skies

Section R806.2 does, however, in comparison with conventional requirements (1/150), this requires drastically less venting area, lowering the amount of required venting space to a minimum of 1/300 of the vented area when compared to conventional needs.

Two criteria must be fulfilled to allow the required venting to be reduced. They are as follows:

  1. In Climate Zones 6, 7, and 8, a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling.
  2. A minimum of 40 percent and not more than 50 percent of the required ventilation area is provided by ventilators positioned in the upper part of the attic or rafter space. Upper ventilators should be no more than 3 feet (914 mm) below the ridge or highest point of a room, measured vertically, and should be no higher than this. The rest of the required ventilation must be found in the lowest one-third of the attic space. Where the framing of a wall or roof runs in conflict with the installation of upper ventilators, installations more than 3 feet below the ridge or peak of the space are permitted.

The first condition stipulates that a vapor barrier is needed in cooler climes and allows for a reduction based on the vapor barrier being installed on the warm-in-winter side of the ceiling.

The second feature considers that attic vents providing cross-ventilation are positioned higher in the attic.

Read more: How many roof vents do I need?

Clearances for Attic Vent and Insulation

Ventilation pipes in silver insulation material on the attic

With the use of attic insulation becoming increasingly widespread, it's vital to ensure that any roof vents that provide attic ventilation are free of obstruction. To avoid insulation from blocking vent holes, the code stipulates that it be kept at least 1 inch away from them.

A minimum of 1 inch must separate roof sheathing and insulation in enclosed rafter rooms when ventilation is supplied to rafter spaces. This process should maintain an air gap of at least 1 inch between the insulation and the roof sheathing. Because all sorts of vents in the attic provide ventilation, this clearance must be maintained throughout the rafter area and throughout the attic for all varieties of openings.

Ventilation in Attic Spaces: Openings for Vents

We spoke about how ventilation apertures must be kept free of rain, snow, birds, and other vermin while still allowing enough breathing room. So let's get down to business with how we should safeguard these openings.

The openings must be no more than 1/4 inch in diameter. If the holes are larger than 1/4 inch, metal or welded wire cloth screening, hardware cloth, perforated vinyl, or similar material with holes not less than 1/16 and no wider than 1/4 inch must be used.

Regardless of the type of vent you choose, it's critical to exercise caution and maintain the vents clear while preventing unwanted visitors' entry.

It's also critical to remember that all required attic ventilation holes should lead straight outside air.